Troubleshooting

Troubleshooting


Alarm Warnings

To Fault find plunger and needle sensors;


  • Select the diagnostics page.
  • With baler making bales check the sensor signal is switching ……0 to 1 back and forth.
  • If it is not switching, shut off the baler.
  • Make sure Weighay is on.
  • Check the led light on the sensor is on when plunger or needle carriage is next to it.
  • Trigger sensor with a metal object


Platform

  • Zero scale
  • Clean trash from around platform
  • Platform unloaded 300 mv approx
  • Loaded with 20kg 1300 mv approx
  • Load cell bare 14mv (alarm set for 50mv minimum)
  • 100kg =5000 mv therefore 1 kg =50 mv.